Ac a coil on downflow install help

AC A coil on Downflow Install - HELP!


My Trane air handler is vertical but upside down cause my system requires a downflow air supply (all ducts below in crawlspace). BUT - the AC A coil is installed right side up (top of A on top). Sooooo, my question is wouldn't there be a problem with condensate flowing into the blower/electric panel below? Seems to me on a normal upflow system the condensate gets blown up from the coil and then drips into a collector. But in a downflow system how is the condensate removed ?? Thanks Gene It runs to drain pan just like in up flow. The drain pan only runs under the perimeter of the coil - the entire middle of the coil is open for air flow. So I guess you are saying that the condensate clings to the metal coils and fins as it runs down into the pan? I would think the sheer velocity of the blower air speed would blow the condensate straight up (or down in a downflow system) onto the surrounding duct work. It will if coil gets dirty. But 99% of the time it will run down the channel to the pan. You dont say just what unit you have there. On a Trane2TEH air handler . For a downflow the A coil is on top of the blower. blowing down. Is this on a manufactured home if the electric heat kit and blower are below the coil there is a history of problems with water getting into the electrical system that is why the manufacturers exclude water damage from the warranty which I think is quite ridiculous because the design is a bad idea (water over electricity, duh) there is a way to combat this you need to keep the unit very coil, drain line and filter and I mean clean if anything is on that coil that will cause the water to drop off before it reaches the bottom of the coil it will drop right on the blower, also there is a device called a wet switch we use in computer rooms that will shut off the system at the slightest accumulation of water. All these things still don't guarantee you won't have a problem because you have water over electricity. Originally Posted by Ed Imeduc You dont say just what unit you have there. On a Trane2TEH air handler . For a downflow the A coil is on top of the blower. blowing down. Its a TWE024P13 - same config as 2TEH - A coil on top of the blower, heat coils, and electric. I got hold of the Trane install doc and seems everything is per the guidelines. I did note that condensate gets blown all over everything below cause I can see traces of mold and also white residue from minerals in the water. I suppose the unit is engineered for this condition as its been in service 5 years with no problems.








Related Posts:




  • Bryant evaporator coil needed

    Bryant Evaporator Coil NeededHi everyone, I just had my A/C serviced and my tech of many years told me that although my Bryant 3.5 ton is only 7 years old, the evaporator coil needs to be replaced...


  • Air handler capacitor problem help

    Air Handler - Capacitor Problem? Help...I need some assistance diagnosing a problem I'm having with my A/C AirHandler/heater. My house has 2 A/C units outside on a cement slab, and 2 Air Handler/H...


  • Diy install aprilaire 500 humidifier couple questions

    DIY install Aprilaire 500 humidifier? Couple questions...I've contemplated putting in a whole-house humidifier a couple times over the past few years, and I'm now fearing the coming dry winter air...


  • Carrier evaporator coil replacement and other considerations

    Carrier Evaporator coil replacement and other considerationsI have a 2.5 Ton Carrier Air Conditioner with the Evaporator coil mounted on top of gas furnace. The unit was low on refrigerant, so the...


  • Aprilaire 700 what is best install location

    Aprilaire 700 - what is best install locationWhen installing an Aprilaire 700, what location is preferable? Unfortunately, my supply plenum is not wide enough for the required opening. That leaves...